baseschematic: ..\..\..\..\..\..\..\DVM_PFC_Continuous_Conduction_Mode.sxsch log_file: ..\..\..\..\..\dvm_advanced.log simulator: simplis screenshot: schematic.png deck: input.deck init: input.deck.init test_argument: Transient|ControlStartup|HL_Maximum|F_Low|Light Load datetimestamp: 12/10/2015 6:23 PM status: RUN feature: DVM PFCOutput#tran scalar: Avg(VPFCOutput_in_reg)=400.098 scalar: Min(VPFCOutput_in_reg)=399.073 scalar: Pk2Pk(VPFCOutput_in_reg)=1.96372 spec: Min_VPFCOutput_in_reg=pass,Min. Output1 Voltage in Reg. (399.073) is greater than or equal to Min. Output1 Voltage Spec (380) scalar: Max(VPFCOutput_in_reg)=401.037 spec: Max_VPFCOutput_in_reg=pass,Max. Output1 Voltage in Reg. (401.037) is less than or equal to Max. Output1 Voltage Spec (420) spec: Pk2Pk_VPFCOutput_in_reg=pass,Pk-to-Pk Output1 Voltage in Reg. (1.96372) is less than or equal to Max. Output1 Voltage Spec (10) scalar: RMS(VPFCOutput_in_reg)=400.099 scalar: Overshoot_VPFCOutput=404.468 spec: Overshoot_VPFCOutput=pass,Max. Output1 Voltage (404.468) is less than or equal to Max. Output1 Voltage Spec (420) scalar: vout1_turn_on_time=30.06m scalar: Frequency(Line)=50 scalar: Max(ILine Inrush Current)=724.567m scalar: RMS(VLine)=265 scalar: RMS(ILine)=173.932m spec: Max_ILine_Inrush=pass,Max. Inrush Current for Line (724.567m) is less than or equal to Max. Inrush Spec of (15) feature: DVM Line,1000 scalar: VPFCOutput %_diff_last_2_linecycles=0.000000927624% spec: AC_Settling(PFCOutput)=pass, Voltage across PFCOutput has settled to (9.27624n) % and is less than or equal to Max Settling Spec of (10m) % scalar: Avg(VPFCOutput Last LineCycle)=400.098 scalar: Avg(VPFCOutput Previous LineCycle)=400.098 scalar: VPFCOutput %_diff_last_2_linecycles=0.000000927624% scalar: Avg(VPFCOutput At Simulation Start Time)=364.131 stats: N/A numgraphs: 3 graphid: 141 graphname: AC#tran sg: simplis_tran6_141 path: simplis_tran6_141.sxgph scalar: Max(VPFCOutput)=404.468 scalar: Min(VPFCOutput)=362.425 scalar: Min(IPFCOutput)=90.6061m scalar: Max(IPFCOutput)=101.117m graphid: 147 graphname: DVM PFCOutput#tran sg: simplis_tran6_147 path: simplis_tran6_147.sxgph curve151:VPFCOutput,FF0000 curve159:IPFCOutput,008000 png: simplis_tran6_147.png scalar: Max(VLine)=374.796 scalar: Min(VLine)=-374.74 scalar: Max(ILine)=724.567m scalar: Min(ILine)=-724.567m graphid: 152 graphname: DVM Line#tran sg: simplis_tran6_152 path: simplis_tran6_152.sxgph curve156:VLine,FF0000 curve157:VAUX,008000 curve161:ILine,0000FF png: simplis_tran6_152.png rstatus: PASS