» DVM Test Report: Transient|LineStartup|LL_Maximum|F_High|Light Load

Test Details
Schematic DVM_PFC_Continuous_Conduction_Mode.sxsch
Test Transient|LineStartup|LL_Maximum|F_High|Light Load
Date / Time 12/10/2015 6:27 PM
Report Directory ac_dc_built_in\Transient\LineStartup\LL_Maximum\F_High\LightLoad
Log File report.txt
Screenshot schematic.png
Status FAIL
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
Frequency(Line) 60
ILine
MIN
-5.36204
MAX
17.3154
RMS
314.312m
ILine Inrush Current
MAX
17.3154
IPFCOutput
MIN
-60.3978E-27
MAX
101.67m
Overshoot_VPFCOutput 406.68
VLine
MIN
-187.27
MAX
190.201
RMS
132
vout1_turn_on_time 409.172m
VPFCOutput
MIN
-241.591E-24
MAX
406.68
VPFCOutput %_diff_last_2_linecycles 0.00767285%
VPFCOutput At Simulation Start Time
AVG
-121.187E-24
VPFCOutput Last LineCycle
AVG
400.157
VPFCOutput Previous LineCycle
AVG
400.188
VPFCOutput_in_reg
AVG
400.323
MIN
399.419
MAX
401.302
RMS
400.324
PK2PK
1.88366
Measured Spec Values
AC_Settling(PFCOutput) PASS: Voltage across PFCOutput has settled to (76.7285u) % and is less than or equal to Max Settling Spec of (10m) %
Max_ILine_Inrush FAIL: Max. Inrush Current for Line (17.3154) is greater than or equal to Max. Inrush Spec of (15)
Max_VPFCOutput_in_reg PASS: Max. Output1 Voltage in Reg. (401.302) is less than or equal to Max. Output1 Voltage Spec (420)
Min_VPFCOutput_in_reg PASS: Min. Output1 Voltage in Reg. (399.419) is greater than or equal to Min. Output1 Voltage Spec (380)
Overshoot_VPFCOutput PASS: Max. Output1 Voltage (406.68) is less than or equal to Max. Output1 Voltage Spec (420)
Pk2Pk_VPFCOutput_in_reg PASS: Pk-to-Pk Output1 Voltage in Reg. (1.88366) is less than or equal to Max. Output1 Voltage Spec (10)
PFCOutput
IPFCOutput
VPFCOutput
SXGPH File simplis_tran8_193.sxgph
Line
VLine
ILine
SXGPH File simplis_tran8_198.sxgph
Other SXGPH Files
AC#tran simplis_tran8_187.sxgph